AVN4B-R-TK552

現行品

IDEC AVN4B-R-TK552

IDEC AVN4B-R-TK552 — IDEC AVN4B-R-TK552

Emergency Stop Switches / E-Stop Switches TWTD Bnt Jmbo for AVD422N-R-TK

仕様一覧

Lead time
0 Days
Mouser part number
199-AVN4BRTK552
Rohs status

取付クイックリファレンス

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

外形寸法

トラブルシューティング

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

購入先

価格帯

$15.2 — $15.2

1 社の販売代理店

主要仕様

Lead time
0 Days
Mouser part number
199-AVN4BRTK552
Rohs status