M22-YED0056

現行品

Eaton Electrical M22-YED0056

Emergency Stop Switches / E-Stop Switches CUSTOM ASSY: M22-PVT45P-MPI, M22-XBK5

研究ノート

1. What this is

M22-YED0056 is an Eaton M22 RMQ-Titan 22mm MODULAR command switch (operator/actuator; contact blocks and mounting are separate parts).

2. Part-number decode

  • Series: M22 (RMQ-Titan)
  • Panel cutout: 22mm
  • Type: operator/actuator
  • Construction: modular (operator, contact block(s), and mounting are separate parts)

3. Compatibility & ordering

Eaton's M22 (RMQ-Titan, 22mm) and E30 / 10250T (30.5mm heavy-duty) are its principal command-switch ranges. As an M22/E30 modular device, the operator/actuator, the contact or LED block(s), and the mounting adapter are ordered separately — a common ordering error is assuming a stored contact is included. Confirm you have all the pieces for a complete device. Match by size (22 / 30.5mm), function (pushbutton/selector/indicator/E-stop), color, illumination, and contact arrangement; cross-reference to Schneider Harmony, Allen-Bradley 800F/800T, Siemens 3SU, or IDEC HW by the same attributes if needed.

4. Data-quality note

The Eaton series, size, and component type are decoded from the part number (grounded in Eaton's Vol.7 catalog and distributor listings). The exact color and contact arrangement depend on the remaining digits and the sub-family — confirm against the Eaton datasheet for a precise order (not guessed here).

5. Sources

  • Eaton control-components catalog (Vol.7) / RMQ-Titan M22 & 10250T (eaton.com)
  • Distributor listing (Newark / Mouser) — search the exact part number

出典
  1. Eaton — M22-YED0056 — eaton.com

仕様一覧

Component type
operator/actuator
Device class
pushbutton
Enriched by
eaton-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
M22 (RMQ-Titan)
Modular
true
Mouser part number
504-M22-YED0056
Panel cutout
22mm
Pn status
decoded
Rohs status
Series description
Eaton M22 RMQ-Titan 22mm MODULAR command switch (operator/actuator; contact blocks and mounting are separate parts)

取付クイックリファレンス

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

外形寸法

トラブルシューティング

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

主要仕様

Component type
operator/actuator
Device class
pushbutton
Enriched by
eaton-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
M22 (RMQ-Titan)