130126-0214

Aktif

Molex 130126-0214

Molex 130126-0214 — Molex 130126-0214

Emergency Stop Switches / E-Stop Switches FOUR-BUTTON STATION W/EMERGENCYSTOP

Research Notes

1. What this is

130126-0214 ("Molex 130126-0214") is catalogued as a emergency-stop device from Molex.

2. What we know

  • Manufacturer: Molex
  • Category: emergency-stop device
  • Part number / name: 130126-0214 — Molex 130126-0214
  • Molex — electronic connectors and interconnect (a Molex part is usually a connector)

3. How to identify / order the exact part

The full specifications for this part are not machine-decodable from the data we hold. To confirm the exact configuration (contacts, rating, colour, mounting, protocol), search the Molex catalog for this part number on the manufacturer site or a distributor (DigiKey / Mouser / RS).

4. Data-quality note

This page is generated from the catalogued manufacturer, category, and product name. Per our keep-and-document policy we publish a page for every part we hold and state plainly what is known versus what needs verification, rather than deleting the row or inventing specs. Flagged needs-verification.

5. Sources

  • Molex product catalog — search "130126-0214" / "Molex 130126-0214"

1 source
  1. Molex 130126-0214 — distributor/catalog

Spesifikasi

Device class
emergency-stop
Enriched by
generic-fallback-2026-08-12
Lead time
0 Days
Mouser part number
538-130126-0214
Pn status
needs-verification
Rohs status
RoHS Compliant

Referensi Cepat Instalasi

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Dimensi

Pemecahan Masalah

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

Tempat Membeli

Kisaran harga

$1.03 — $1.03

di 1 distributor

Spesifikasi Cepat

Device class
emergency-stop
Enriched by
generic-fallback-2026-08-12
Lead time
0 Days
Mouser part number
538-130126-0214
Pn status