87941-08

Aktif

Honeywell 87941-08

Honeywell 87941-08 — Honeywell 87941-08

Emergency Stop Switches / E-Stop Switches DPST-NO in push EMERGENCY STOP

Research Notes

1. What this is

87941-08 is a Honeywell Honeywell component — line not recognized.

2. Part-number decode

  • Series: Honeywell Honeywell (line not recognized)
  • Type: switch

3. Compatibility & ordering

Honeywell (incl. MICRO SWITCH) makes AML pushbuttons/indicators and snap-action/basic switches. Match by type, actuation, illumination, sealing, and mounting, then use the manufacturer datasheet to confirm the exact contact and termination encoded in the part number.

4. Data-quality note

The exact Honeywell product line/configuration could not be confidently decoded from this part number. Kept and documented; flagged needs-verification.

5. Sources

  • Honeywell product catalog (sps.honeywell.com)
  • Distributor listing (DigiKey / Mouser) — search the exact part number

1 source
  1. Honeywell — 87941-08 — sps.honeywell.com

Spesifikasi

Enriched by
honeywell-decoder-2026-08-12
Lead time
49 Days
Manufacturer series
Honeywell (line not recognized)
Mouser part number
785-08794108
Pn status
needs-verification
Rohs status
RoHS Compliant
Series description
Honeywell switch component — exact line/config could not be decoded from this part number; kept and flagged for verification

Referensi Cepat Instalasi

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Dimensi

Pemecahan Masalah

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

Tempat Membeli

Kisaran harga

$147.68 — $147.68

di 1 distributor

Spesifikasi Cepat

Enriched by
honeywell-decoder-2026-08-12
Lead time
49 Days
Manufacturer series
Honeywell (line not recognized)
Mouser part number
785-08794108
Pn status