800F-A7A7
Aktif22mm Black Flush Push Button
Allen-Bradley 800F black flush push button.
Aplikasi Umum
Black has no specific IEC 60204-1 safety meaning. Used for auxiliary non-critical functions — counter reset, lamp test, horn acknowledge, mode select. Keeps the safety-colored buttons visually distinct.
Research Notes
1. What this is
800F-A7A7 does not correspond to a real Allen-Bradley product. It was recorded in this catalog as "22mm Black Flush Push Button", but the code violates Rockwell's actual Bulletin 800F naming and returns no manufacturer or distributor results. If you found this exact code somewhere, it is almost certainly auto-generated or mistyped — treat it as non-existent.
2. Why it isn't real
Rockwell's genuine Bulletin 800F 22 mm pilot-device system uses:
- Colors as DIGITS, never letters: 1 = white, 3 = green, 4 = red, 5 = yellow, 6 = blue, 7 = black. Codes like "A7", "A1", "A4M1", "A8A8", "LW4" have no valid color field (there is no "A#" color, and 800F has no orange).
- Operators with actuator letters — e.g. 800FP-F3 (green flush), 800FP-F4 (red flush), 800FP-E3 (green extended). See the genuine operator entries in this catalog (#524 800FP-F3, #525 800FP-F4).
- Separate contact blocks — 800F-X10 (1 NO), 800F-X01 (1 NC) — that latch onto the operator (#523). 800F does not ship "complete/enclosed stations"; enclosed pushbutton stations are a different Rockwell line (800T / 800H, 30.5 mm).
3. What you probably want instead
For a black flush 800F pushbutton, the real code is 800FP-F7 (7 = black), plus a contact block (800F-X10 = 1 NO / 800F-X01 = 1 NC).
4. Why this page exists (data-quality)
Kept deliberately. The Button Index ranks for this exact code, so rather than show a misleading spec sheet, this page tells you the code isn't a real product and points you to the genuine 800F system. Flagged pn_status: fabricated. If you have a source proving otherwise, it can be reinstated.
2 sources
- Allen-Bradley Bulletin 800F 22mm push buttons (genuine naming) — rockwellautomation.com
- 800F 22mm Push Button Specifications / catalog-number decoder — rockwellautomation.com
Spesifikasi
|
Actuator Function
Momentary = springs back when released. Maintained/latching = stays pressed until pressed again.
|
Momentary
|
|
Actuator Type
The button head style. Flush sits level with the bezel (prevents accidental presses). Extended protrudes for easy access.
|
Flush
|
|
Certifications
Third-party safety certifications. UL = required for US NEC installations. CE = EU compliance. CSA = Canadian standards.
|
UL, CSA, CE
|
|
Color
Button/actuator color. Green = start/go, Red = stop/emergency, Yellow = caution, Blue = reset (per IEC 60204-1).
|
Black
|
|
Contact Configuration
Normally Open — circuit is off until you press. Standard for start/go/enable functions.
|
1NO
|
|
Cutout Diameter
The hole size you drill in your panel to mount this button. 22mm is the most common industrial standard worldwide.
|
22mm
|
|
IP Rating
IP66: Dust-tight and withstands powerful water jets from any direction. Standard for outdoor and washdown applications.
|
IP66
|
|
Pn notes
|
Fabricated 800F PN — letter-coded actuator/color violates Rockwell's real scheme (actuator codes F/G/E/R; colors are DIGITS: 1 white/3 green/4 red/5 yellow/6 blue/7 black). 0 distributor hits. Re-key to genuine 800FP-/800FM- by intended color/type, or remove.
|
|
Pn status
|
fabricated
|
Referensi Cepat Instalasi
Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).
Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.
Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.
Dimensi
Diagram Pengkabelan
Pemecahan Masalah
Button doesn't respond when pressed
Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.
Works intermittently
Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.
Button feels mushy or doesn't click
The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.
Tempat Membeli
Kisaran harga
$26.36 — $31.61
di 2 distributor
Spesifikasi Cepat
- Actuator Function
- Momentary
- Actuator Type
- Flush
- Certifications
- UL, CSA, CE
- Color
- Black
- Contact Configuration
- 1NO
Apa Kata Mereka
“Black has no specific IEC 60204-1 safety meaning. Used for auxiliary non-critical functions — counter reset, lamp test, horn acknowledge, mode select. Keeps the safety-colored buttons visually distinc”