XER6022-011C3

सक्रिय

Omron Automation and Safety XER6022-011C3

Emergency Stop Switches / E-Stop Switches

Research Notes

1. What this is

XER6022-011C3 is an Omron Omron component — line not recognized.

2. Part-number decode

  • Series: Omron Omron (line not recognized)
  • Type: switch

3. Compatibility & ordering

Omron makes industrial command switches (A22 22mm, A16 16mm — unitized, contact in the model code), illuminated pushbuttons/pilot lights (A3, M2), and a widely-used B3 PCB tactile-switch family. Match by size, function (pushbutton/selector/indicator/E-stop), colour, illumination, and contact arrangement, then use the Omron datasheet to confirm the exact colour and voltage encoded in the part number.

4. Data-quality note

The exact Omron product line/configuration could not be confidently decoded from this part number. Kept and documented; flagged needs-verification.

5. Sources

  • Omron product catalog (omron.com / components.omron.com)
  • Distributor listing (DigiKey / Mouser) — search the exact part number

1 source
  1. Omron — XER6022-011C3 — omron.com

स्पेसिफिकेशन

Enriched by
omron-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
Omron (line not recognized)
Mouser part number
653-XER6022-011C3
Pn status
needs-verification
Rohs status
Series description
Omron switch component — exact product line/config could not be decoded from this part number; kept and flagged for verification rather than guessed

इंस्टॉलेशन त्वरित संदर्भ

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

आयाम

समस्या निवारण

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

कहाँ से खरीदें

मूल्य सीमा

$1.05 — $1.05

1 वितरकों से

संक्षिप्त स्पेसिफिकेशन

Enriched by
omron-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
Omron (line not recognized)
Mouser part number
653-XER6022-011C3
Pn status
needs-verification