LEO-S595-WBG0

सक्रिय

Advantech LEO-S595-WBG0

Advantech LEO-S595-WBG0 — Advantech LEO-S595-WBG0

Emergency Stop Switches / E-Stop Switches LEO-S LoRaWAN Smart Button 915

Research Notes

1. What this is

LEO-S595-WBG0 ("Advantech LEO-S595-WBG0") is catalogued as a emergency-stop device from Advantech.

2. What we know

  • Manufacturer: Advantech
  • Category: emergency-stop device
  • Part number / name: LEO-S595-WBG0 — Advantech LEO-S595-WBG0
  • Advantech — see the manufacturer's catalog for this part.

3. How to identify / order the exact part

The full specifications for this part are not machine-decodable from the data we hold. To confirm the exact configuration (contacts, rating, colour, mounting, protocol), search the Advantech catalog for this part number on the manufacturer site or a distributor (DigiKey / Mouser / RS).

4. Data-quality note

This page is generated from the catalogued manufacturer, category, and product name. Per our keep-and-document policy we publish a page for every part we hold and state plainly what is known versus what needs verification, rather than deleting the row or inventing specs. Flagged needs-verification.

5. Sources

  • Advantech product catalog — search "LEO-S595-WBG0" / "Advantech LEO-S595-WBG0"

1 source
  1. Advantech LEO-S595-WBG0 — distributor/catalog

स्पेसिफिकेशन

Device class
emergency-stop
Enriched by
generic-fallback-2026-08-12
Lead time
112 Days
Mouser part number
923-LEO-S595-WBG0
Pn status
needs-verification
Rohs status
RoHS Compliant

इंस्टॉलेशन त्वरित संदर्भ

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

आयाम

समस्या निवारण

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

कहाँ से खरीदें

मूल्य सीमा

$59.94 — $59.94

1 वितरकों से

संक्षिप्त स्पेसिफिकेशन

Device class
emergency-stop
Enriched by
generic-fallback-2026-08-12
Lead time
112 Days
Mouser part number
923-LEO-S595-WBG0
Pn status
needs-verification