CE3K1-10B-11

सक्रिय

ABB CE3K1-10B-11

ABB CE3K1-10B-11 — ABB CE3K1-10B-11

Emergency Stop Switches / E-Stop Switches CMPT ESTOP BLK KEY 30MM 1-1

Research Notes

1. What this is

CE3K1-10B-11 is a ABB CE command switch.

2. Part-number decode

  • Series: ABB CE3/CE4
  • Type: command switch
  • Panel cutout: 22mm

3. Compatibility & ordering

ABB makes Modular (MP metal / CP plastic) 22mm command switches, CE compact switches, KP mushroom operators, and Jokab (2TLA) safety products. Match by type, actuation, illumination, sealing, and mounting, then use the manufacturer datasheet to confirm the exact contact and termination encoded in the part number.

4. Data-quality note

The ABB product line/type is identified; the detailed configuration is left to the datasheet rather than guessed. Flagged decoded-partial.

5. Sources

  • ABB product catalog (abb.com)
  • Distributor listing (DigiKey / Mouser) — search the exact part number

1 source
  1. ABB — CE3K1-10B-11 — abb.com

स्पेसिफिकेशन

Device class
command switch
Enriched by
abb-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
CE3/CE4
Mouser part number
894-CE3K1-10B-11
Panel cutout
22mm
Pn status
decoded-partial
Rohs status
Series description
ABB CE-series 22mm modular command switch (compact pushbutton/indicator; operator + contact block)

इंस्टॉलेशन त्वरित संदर्भ

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

आयाम

समस्या निवारण

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

कहाँ से खरीदें

मूल्य सीमा

$48.99 — $48.99

1 वितरकों से

संक्षिप्त स्पेसिफिकेशन

Device class
command switch
Enriched by
abb-decoder-2026-08-12
Lead time
0 Days
Manufacturer series
CE3/CE4
Mouser part number
894-CE3K1-10B-11