ITS40FR2ST

Aktiivne

C&K ITS40FR2ST

C&K ITS40FR2ST — C&K ITS40FR2ST

Tactile Switches Rt. Angle thru-hole Blue LED, no cap

Spetsifikatsioonid

Device class
tactile switch
Enriched by
ck-decoder-2026-08-12
Lead time
84 Days
Manufacturer series
K-series tactile
Mouser part number
611-ITS40FR2ST
Pn status
decoded
Rohs status
RoHS Compliant
Series description
C&K tactile switch (K-series: KSC/KSA/KSR/KSL/KST/KSI/KMR/KMT/KXT etc., plus ITS/SSF — high-reliability PCB tact switch, many with sealed IP-rated and low-profile options)

Paigalduse kiirjuhend

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

Mõõtmed

Veaotsing

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.