K1161511

Activo

TE Connectivity K1161511

TE Connectivity K1161511 — TE Connectivity K1161511

Emergency Stop Switches / E-Stop Switches Emergency switch ES-2012-T211

Research Notes

1. What this is

K1161511 ("TE Connectivity K1161511") is catalogued as a emergency-stop device from TE Connectivity.

2. What we know

  • Manufacturer: TE Connectivity
  • Category: emergency-stop device
  • Part number / name: K1161511 — TE Connectivity K1161511
  • TE Connectivity — connectors, switches, and sensors for electronics and industrial use

3. How to identify / order the exact part

The full specifications for this part are not machine-decodable from the data we hold. To confirm the exact configuration (contacts, rating, colour, mounting, protocol), search the TE Connectivity catalog for this part number on the manufacturer site or a distributor (DigiKey / Mouser / RS).

4. Data-quality note

This page is generated from the catalogued manufacturer, category, and product name. Per our keep-and-document policy we publish a page for every part we hold and state plainly what is known versus what needs verification, rather than deleting the row or inventing specs. Flagged needs-verification.

5. Sources

  • TE Connectivity product catalog — search "K1161511" / "TE Connectivity K1161511"

1 source
  1. TE Connectivity K1161511 — distributor/catalog

Especificaciones

Device class
emergency-stop
Enriched by
generic-fallback-2026-08-12
Lead time
158 Days
Mouser part number
571-K1161511
Pn status
needs-verification
Rohs status

Referencia rápida de instalación

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Dimensiones

Solución de problemas

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

Dónde comprar

Rango de precios

$39.04 — $39.04

en 1 distribuidores

Especificaciones rápidas

Device class
emergency-stop
Enriched by
generic-fallback-2026-08-12
Lead time
158 Days
Mouser part number
571-K1161511
Pn status
needs-verification