Emergency Stop Switches / E-Stop Switches PBES16 28 INCA 48V AC/DC 25mA 000 1NC
Research Notes
1. What this is
2381880-7 is a TE/Alcoswitch TE numeric-series switch.
2. Part-number decode
- Series: TE/Alcoswitch numeric series
- Type: switch
3. Compatibility & ordering
TE Connectivity / Alcoswitch makes pushbutton, toggle, slide, and tactile switches for electronics and industrial equipment. Match by type, actuation, illumination, sealing, and mounting, then use the manufacturer datasheet to confirm the exact contact and termination encoded in the part number.
4. Data-quality note
The TE/Alcoswitch product line/type is identified; the detailed configuration is left to the datasheet rather than guessed. Flagged decoded-partial.
5. Sources
- TE/Alcoswitch product catalog (te.com)
- Distributor listing (DigiKey / Mouser) — search the exact part number
1 source
- TE/Alcoswitch — 2381880-7 — te.com
Specifikace
|
Device class
|
switch/component
|
|
Enriched by
|
te-alcoswitch-decoder-2026-08-12
|
|
Lead time
|
140 Days
|
|
Manufacturer series
|
numeric series
|
|
Mouser part number
|
655-2381880-7
|
|
Pn status
|
decoded-partial
|
|
Rohs status
|
RoHS Compliant
|
|
Series description
|
TE Connectivity numeric-series switch or switch component (toggle/rocker/tactile; the leading 'n-' is a packaging/reel prefix). Exact type per the TE datasheet
|
Stručný průvodce instalací
Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).
Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.
Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.
Rozměry
Řešení problémů
E-stop won't reset (twist/pull doesn't release)
Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.
Machine doesn't stop when e-stop is pressed
Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.
Safety relay faults after e-stop reset
The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.
Stručné specifikace
- Device class
- switch/component
- Enriched by
- te-alcoswitch-decoder-2026-08-12
- Lead time
- 140 Days
- Manufacturer series
- numeric series
- Mouser part number
- 655-2381880-7