Emergency Stop Switches / E-Stop Switches PENDANT CONTROL STATION YELLOW
Research Notes
1. What this is
XACA4812 ("APC by Schneider Electric XACA4812") is catalogued as a emergency-stop device from APC by Schneider Electric.
2. What we know
- Manufacturer: APC by Schneider Electric
- Category: emergency-stop device
- Part number / name: XACA4812 — APC by Schneider Electric XACA4812
- APC by Schneider Electric — see the manufacturer's catalog for this part.
3. How to identify / order the exact part
The full specifications for this part are not machine-decodable from the data we hold. To confirm the exact configuration (contacts, rating, colour, mounting, protocol), search the APC by Schneider Electric catalog for this part number on the manufacturer site or a distributor (DigiKey / Mouser / RS).
4. Data-quality note
This page is generated from the catalogued manufacturer, category, and product name. Per our keep-and-document policy we publish a page for every part we hold and state plainly what is known versus what needs verification, rather than deleting the row or inventing specs. Flagged needs-verification.
5. Sources
- APC by Schneider Electric product catalog — search "XACA4812" / "APC by Schneider Electric XACA4812"
1 source
- APC by Schneider Electric XACA4812 — distributor/catalog
Specifikace
|
Device class
|
emergency-stop
|
|
Enriched by
|
generic-fallback-2026-08-12
|
|
Lead time
|
0 Days
|
|
Mouser part number
|
996-XACA4812
|
|
Pn status
|
needs-verification
|
|
Rohs status
|
RoHS Compliant
|
Stručný průvodce instalací
Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).
Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.
Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.
Rozměry
Řešení problémů
E-stop won't reset (twist/pull doesn't release)
Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.
Machine doesn't stop when e-stop is pressed
Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.
Safety relay faults after e-stop reset
The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.
Stručné specifikace
- Device class
- emergency-stop
- Enriched by
- generic-fallback-2026-08-12
- Lead time
- 0 Days
- Mouser part number
- 996-XACA4812
- Pn status
- needs-verification