Telemecanique · XB2 Series

XB2-BS8445

Active
CE

XB2 E-Stop Twist Release 40mm

Telemecanique XB2 Series Introduced circa 1985

Telemecanique XB2 emergency stop — legacy e-stop.

Common Applications

Legacy Telemecanique e-stop found on 1985-2003 European machinery. Direct replacement: Schneider ZB4-BS844. The mounting hole and contact blocks are the same — a ZB4 head drops right into an XB2 mounting hole.

Specifications

Actuator Function
Twist-release
Actuator Type
Mushroom 40mm
Certifications
CE
Color
Red
Contact Configuration
1NC
Cutout Diameter
22mm

Installation Quick Reference

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Dimensions

Front 22mm cutout 40mm head Side panel terminals

Wiring Diagram

L T 21 22 NC (closed) opens on press

Troubleshooting

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

Where to Buy

Price range

$40.91 — $62.49

across 2 distributors

Quick Specs

Actuator Function
Twist-release
Actuator Type
Mushroom 40mm
Certifications
CE
Color
Red
Contact Configuration
1NC

What People Are Saying

+

“Legacy Telemecanique e-stop found on 1985-2003 European machinery. Direct replacement: Schneider ZB4-BS844. The mounting hole and contact blocks are the same — a ZB4 head drops right into an XB2 mount”

Reddit r/PLC 12 upvotes View thread →