Allen-Bradley · 800F السلسلة

800F-A4A2

نشط
UL CSA CE

22mm Red Flush Push Button 1NC

Allen-Bradley 800F السلسلة Introduced circa 2005

Allen-Bradley 800F series red flush momentary push button with 1NC contact block.

التطبيقات الشائعة

Standard stop button on Allen-Bradley panels. Pairs with 800F-A3A1 green start. Red color and 1NC contact follow NFPA 79.

المواصفات

Actuator Function
Momentary
Actuator Type
Flush
Certifications
UL, CSA, CE
Color
Red
Contact Configuration
1NC
Cutout Diameter
22mm
IP Rating
IP66
Material
Plastic with chrome bezel
Mounting Type
Panel

مرجع سريع للتركيب

Panel cutout: 22mm. Insert from the front of the panel, secure with mounting nut from behind (tighten to 2-3 Nm).

Contact block: Snap or screw the contact block onto the rear of the button body. Ensure the contact block orientation matches the wiring diagram — NO terminals are usually marked.

Wiring: Use 0.5-2.5mm² stranded wire with ferrules. Tighten screw terminals to 0.8 Nm. Test the button function before energizing the circuit.

الأبعاد

Front 22mm cutout panel hole diameter Side panel contact ~45mm depth

مخطط التوصيل

L T 21 22 NC (closed) opens on press

استكشاف الأعطال وإصلاحها

Button doesn't respond when pressed

Check the contact block first — it's the most common failure point. Test continuity across the NO or NC terminals with a multimeter. If no click is felt, the return spring in the head may be broken.

Works intermittently

Contact block contacts are pitted or burned. Replace the contact block — don't try to file the contacts. Check if the rated cycle count has been exceeded.

Button feels mushy or doesn't click

The spring return mechanism in the button head is worn. Replace the head. The contact block can usually be reused if it tests OK.

أين تشتري

نطاق السعر

$23.78 — $40.36

عبر 2 موزع

مواصفات سريعة

Actuator Function
Momentary
Actuator Type
Flush
Certifications
UL, CSA, CE
Color
Red
Contact Configuration
1NC

ما يقوله المستخدمون

+

“Hundreds of these across our plants. Not a single failure in 10 years that wasnt caused by physical damage. The integrated contact block means fewer parts to assemble.”

Reddit r/PLC by maintenance_mgr 22 تصويتات إيجابية عرض الموضوع →