E200-R22-C10R

Active

E-Switch E200-R22-C10R

E-Switch E200-R22-C10R — E-Switch E200-R22-C10R

Emergency Stop Switches / E-Stop Switches ESTOP,DPDT,8A,5A AC / 6A,200mA DC,Red

Research Notes

1. What this is

E200-R22-C10R is an E-Switch LED indicator.

2. Part-number decode

  • Series: E-Switch LED indicator
  • Type: LED indicator

3. Compatibility & ordering

E-Switch makes tactile, pushbutton (incl. anti-vandal/illuminated), toggle, slide, and appliance switches for electronics and industrial controls. Match by type, actuation (momentary/maintained), illumination, sealing, and mounting, then use the E-Switch datasheet to confirm the exact contact form and termination encoded in the part number.

4. Data-quality note

The E-Switch product line/type is identified; the detailed configuration is left to the datasheet rather than guessed. Flagged decoded-partial.

5. Sources

  • E-Switch product catalog (e-switch.com)
  • Distributor listing (DigiKey / Mouser) — search the exact part number

1 source
  1. E-Switch — E200-R22-C10R — e-switch.com

Specifications

Device class
LED indicator
Enriched by
eswitch-decoder-2026-08-12
Lead time
81 Days
Manufacturer series
LED indicator
Mouser part number
612-E200-R22-C10R
Pn status
decoded-partial
Rohs status
RoHS Compliant
Series description
E-Switch LED indicator / panel-mount LED (E-Switch also supplies discrete and panel LED indicators — L16/LL/GS/E-series)

Installation Quick Reference

Panel cutout: 22mm. Mount with the yellow backing plate visible (required by EN/ISO 13850).

Wiring: Wire NC contacts in series with the safety relay input channels. Use dual-channel wiring for SIL 3 / PLe applications. Never wire directly to a motor contactor.

Testing: Press the e-stop and verify the machine stops within the required time. Test the reset mechanism. Repeat monthly per EN/ISO 13850.

Dimensions

Troubleshooting

E-stop won't reset (twist/pull doesn't release)

Check for debris in the mechanism. For twist-release: turn clockwise 45-90 degrees. For push-pull: pull straight out firmly. If the mechanism is stuck, the internal latch may be damaged — replace the entire head assembly.

Machine doesn't stop when e-stop is pressed

Critical safety issue. Immediately lock out the machine. Check wiring — NC contacts must be in series with the safety relay. Verify the safety relay is functioning. A broken wire in an NC circuit should cause a stop, so check for a wiring bypass.

Safety relay faults after e-stop reset

The safety relay detects a cross-fault between the two monitoring channels. Check that both NC contacts on the e-stop are switching simultaneously. One contact may be welded closed — replace the contact block.

Photos & Drawings

Images: mouser.com

Quick Specs

Device class
LED indicator
Enriched by
eswitch-decoder-2026-08-12
Lead time
81 Days
Manufacturer series
LED indicator
Mouser part number
612-E200-R22-C10R